Application
The cables are designed for use as subscriber distribution cables and as connection
between central offices. The recommended installation is in ducts
Standards
• RUS (REA) PE-39 (RUS 7 CFR 1755.390)
• ICEA S-84-608
Construction
Conductors
Solid annealed bare copper, 0.4/0.5/0.63/0.9mm, as per ASTM B-3/class 1 of IEC 60228
Isolation
Solid medium or high density polyethylene as per ASTM D 1248/IEC 60708
Twisted Pairs
Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk
Elément de câblage
Twisted Pairs
Cable Core Assemblée
Cables of 25 pairs or less are assembled into cylindrical core. Cables larger than 25 pairs are assembled into units, which are then used to form the core. Units are identified by colour coded binders
Core Wrapping
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors
Moisture Barrier
A layer of corrugated PE copolymer coated aluminium tape (0.2mm/8mil) is applied longitudinally with overlap over the cable core to provide 100% electrical shielding coverage and ensure a barrier against water vapor
Gaine
Black low or medium density polyethylene as per ASTM D 1248/IEC 60708, being able to withstand exposure to sunlight, temperature variations, ground chemicals and other environmental contaminants
Ripcord
Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal
Paires de rechange (optional)
Spare pairs may be provided for large pair cables
Continuity Wire (optional)
One tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen
Electrical Properties
Chef d'orchestre Diamètre nominale |
mm |
0.4 |
0.5 |
0.63 |
0.9 |
Chef d'orchestre Gauge Size |
AWG |
26 |
24 |
22 |
19 |
Maximum Moyenne DC Resistance |
Ω/km / Ω/mile |
140/225 |
87/140 |
55/88.6 |
27.0/43.4 |
Maximum individuelle DC Resistance |
Ω/km / Ω/mile |
144.2/232 |
89.5/144 |
56.5/91.0 |
28.0/45.0 |
Minimum de résistance d'isolement @500V DC |
MΩ.km / MΩ.mile |
1600/1000 |
1600/1000 |
1600/1000 |
1600/1000 |
Maximum Moyenne Résistance Unbalance |
% |
1.5 |
1.5 |
1.5 |
1.5 |
Maximum de résistance individuelle Unbalance |
% |
5 |
5 |
5 |
5 |
Moyenne Mutual Capacitance |
nF/km / nF/kft |
48.5-54.0
/14.8-16.5 |
48.5-54.0
/14.8-16.5 |
48.5-54.0
/14.8-16.5 |
48.5-54.0
/14.8-16.5 |
Capacité maximale de placement individuels |
nF/km / nF/kft |
57/17.4 |
57/17.4 |
57/17.4 |
57/17.4 |
Capacité maximale individuelle Unbalance pair-à-pair |
pF/km / pF/kft |
145/44 |
145/44 |
145/44 |
145/44 |
Capacitance Unbalance RMS pair-à-pair |
pF/km / pF/kft |
45/13.7 |
45/13.7 |
45/13.7 |
45/13.7 |
Capacité maximale individuelle Unbalance pair-à-terre |
pF/km / pF/kft |
2625/800 |
2625/800 |
2625/800 |
2625/800 |
Maximum Moyenne Capacitance Unbalance pair-à-terre |
pF/km / pF/kft |
574/175 |
574/175 |
574/175 |
574/175 |
Chef d'orchestre de résistance de boucle maximale @20°C |
Ω/km / Ω/mile |
300/482 |
192/309 |
114/183.6 |
60/96.4 |
Impédance @1KHz |
Ω |
994 |
796 |
660 |
445 |
Impédance @100KHz |
Ω |
147 |
134 |
125 |
122 |
Impédance@512KHz |
Ω |
120 |
118 |
117 |
116 |
Impédance @1MHz |
Ω |
117 |
115 |
114 |
113 |
Maximum Moyenne Attenuation @0.8KHz |
dB/km / dB/kft |
1.64/0.5 |
1.30/0.39 |
1.04/0.32 |
0.74/0.22 |
Maximum Moyenne Attenuation @1KHz |
dB/km / dB/kft |
1.68/0.51 |
1.35/0.41 |
1.08/0.33 |
0.76/0.23 |
Maximum Moyenne Attenuation @3KHz |
dB/km / dB/kft |
3.18/0.97 |
2.52/0.77 |
2.01/0.61 |
1.42/0.43 |
Maximum Moyenne Attenuation@150KHz |
dB/km / dB/kft |
11.4/3.47 |
8.3/2.53 |
6.2/1.89 |
4.4/1.34 |
Maximum Moyenne Attenuation @772KHz |
dB/km / dB/kft |
24.3/7.4 |
19.4/5.9 |
15.4/4.7 |
10.8/3.3 |
Maximum Moyenne Attenuation @1000KHz |
dB/km / dB/kft |
27.1/8.25 |
21.4/6.52 |
17.5/5.33 |
12.8/3.89 |
Résistance diélectrique |
|
|
|
|
|
Chef d'orchestre à l'orchestre (3secs) |
V DC |
2400 |
3000 |
4000 |
5000 |
Chef d'orchestre à l'écran (3secs) |
V DC |
10000 |
10000 |
10000 |
10000 |
Minimum EL Far-end Cross-talk-Mean Power Sum |
|
|
|
|
|
@150KHz |
dB/305m / dB/kft |
61 |
63 |
63 |
65 |
@772KHz |
dB/305m / dB/kft |
47 |
49 |
49 |
57 |
@1.6MHz |
dB/305m / dB/kft |
41 |
42 |
43 |
44 |
@3.15MHz |
dB/305m / dB/kft |
35 |
37 |
37 |
39 |
@6.3MHz |
dB/305m / dB/kft |
29 |
31 |
31 |
33 |
Minimum Far-end Cross-talk-Worst Pair Power Sum |
|
|
|
|
|
@150KHz |
dB/305m / dB/kft |
57 |
57 |
57 |
59 |
@772KHz |
dB/305m / dB/kft |
43 |
43 |
43 |
45 |
@1.6MHz |
dB/305m / dB/kft |
37 |
37 |
37 |
39 |
@3.15MHz |
dB/305m / dB/kft |
31 |
31 |
31 |
33 |
@6.3MHz |
dB/305m / dB/kft |
25 |
25 |
25 |
27 |
Minimum Near-end Cross-talk-Mean Power Sum |
|
|
|
|
|
@150KHz |
dB/305m / dB/kft |
58 |
58 |
58 |
58 |
@772KHz |
dB/305m / dB/kft |
47 |
47 |
47 |
47 |
@1.6MHz |
dB/305m / dB/kft |
43 |
43 |
43 |
43 |
@3.15MHz |
dB/305m / dB/kft |
38 |
38 |
38 |
38 |
@6.3MHz |
dB/305m / dB/kft |
34 |
34 |
34 |
34 |
Minimum Near-end Cross-talk-Worst Pair Power Sum |
|
|
|
|
|
@150KHz |
dB/305m / dB/kft |
53 |
53 |
53 |
53 |
@772KHz |
dB/305m / dB/kft |
42 |
42 |
42 |
42 |
@1.6MHz |
dB/305m / dB/kft |
38 |
38 |
38 |
38 |
@3.15MHz |
dB/305m / dB/kft |
33 |
33 |
33 |
33 |
@6.3MHz |
dB/305m / dB/kft |
29 |
29 |
29 |
29 |
Nominal Insulation Thickness |
mm |
0.15 |
0.2 |
0.26 |
0.3 |
Nominal Insulated Conductor Diameter |
mm |
0.7 |
0.9 |
1.15 |
1.5 |
Mechanical and Thermal Properties
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 10 x Overall Diameter (unarmoured cables);15 x Overall Diameter (armoured cables)
Colour Code
Standard colour code is per ICEA S-84-608 given in Colour Code Chart
Dimensions And Weight
Solid PE Insulated & LAP Sheathed Jelly Filled Cables to RUS (REA) PE-39 (ICEA S-84-608)
Cable Code |
Nombre de paires |
Gaine Epaisseur minimum
mm |
Diamètre maximum
mm |
Poids nominal
kg/km |
0.4mm Conductor, 0.7mm Insulated Wire |
TP39-2YF(L)2Y-25P04 |
25 |
1.5/0.059 |
14.0/0.551 |
203/136 |
TP39-2YF(L)2Y-50P04 |
50 |
1.5/0.059 |
17.1/0.673 |
326/219 |
TP39-2YF(L)2Y-75P04 |
75 |
1.5/0.059 |
19.5/0.768 |
446/300 |
TP39-2YF(L)2Y-100P04 |
100 |
1.7/0.067 |
22.0/0.866 |
569/382 |
TP39-2YF(L)2Y-150P04 |
150 |
1.7/0.059 |
25.7/1.012 |
827/556 |
TP39-2YF(L)2Y-200P04 |
200 |
1.7/0.067 |
28.7/1.130 |
1023/687 |
TP39-2YF(L)2Y-300P04 |
300 |
1.8/0.071 |
33.6/1.323 |
1451/975 |
TP39-2YF(L)2Y-400P04 |
400 |
1.9/0.075 |
37.8/1.488 |
1876/1261 |
TP39-2YF(L)2Y-600P04 |
600 |
2.0/0.079 |
45.8/1.803 |
2781/1869 |
TP39-2YF(L)2Y-900P04 |
900 |
2.1/0.083 |
54.7/2.154 |
4057/2726 |
0.5mm Conductor, 0.9mm Insulated Wire |
TP39-2Y(L)2Y-6P05 |
6 |
1.5/0.059 |
11.3/0.445 |
123/83 |
TP39-2Y(L)2Y-12P05 |
12 |
1.5/0.059 |
13.3/0.524 |
180/121 |
TP39-2Y(L)2Y-18P05 |
18 |
1.7/0.067 |
14.9/0.587 |
233/157 |
TP39-2Y(L)2Y-25P05 |
25 |
1.7/0.067 |
16.3/0.642 |
285/192 |
TP39-2Y(L)2Y-50P05 |
50 |
1.7/0.067 |
20.4/0.803 |
478/321 |
TP39-2Y(L)2Y-75P05 |
75 |
1.8/0.071 |
23.8/0.937 |
673/452 |
TP39-2Y(L)2Y-100P05 |
100 |
2.0/0.079 |
27.0/1.063 |
869/584 |
TP39-2Y(L)2Y-150P05 |
150 |
2.2/0.087 |
31.6/1.244 |
1273/855 |
TP39-2Y(L)2Y-200P05 |
200 |
2.4/0.094 |
35.4/1.394 |
1579/1061 |
TP39-2Y(L)2Y-300P05 |
300 |
2.5/0.098 |
42.5/1.673 |
2307/1550 |
TP39-2Y(L)2Y-400P05 |
400 |
2.5/0.098 |
48.4/1.906 |
3026/2033 |
TP39-2Y(L)2Y-600P05 |
600 |
2.5/0.098 |
57.9/2.280 |
4429/2976 |
0.63mm Conductor, 1.15mm Insulated Wire |
TP39-2Y(L)2Y-6P063 |
6 |
1.5/0.059 |
12.6/0.496 |
158/106 |
TP39-2Y(L)2Y-12P063 |
12 |
1.5/0.059 |
15.1/0.594 |
240/161 |
TP39-2Y(L)2Y-18P063 |
18 |
1.7/0.067 |
17.0/0.669 |
317/213 |
TP39-2Y(L)2Y-25P063 |
25 |
1.7/0.067 |
18.9/0.744 |
398/267 |
TP39-2Y(L)2Y-50P063 |
50 |
1.7/0.067 |
24.3/0.957 |
696/468 |
TP39-2Y(L)2Y-75P063 |
75 |
1.8/0.071 |
28.2/1.110 |
984/661 |
TP39-2Y(L)2Y-100P063 |
100 |
1.9/0.075 |
32.2/1.268 |
1278/859 |
TP39-2Y(L)2Y-150P063 |
150 |
2.1/0.083 |
38.0/1.496 |
1898/1275 |
TP39-2Y(L)2Y-200P063 |
200 |
2.2/0.087 |
43.4/1.709 |
2405/1616 |
TP39-2Y(L)2Y-300P063 |
300 |
2.2/0.087 |
52.0/2.047 |
3516/2363 |
TP39-2Y(L)2Y-400P063 |
400 |
2.2/0.087 |
59.2/2.331 |
4614/3100 |
0.9mm Conductor, 1.5mm Insulated Wire |
TP39-2Y(L)2Y-6P09 |
6 |
1.5/0.059 |
15.3/0.602 |
244/164 |
TP39-2Y(L)2Y-12P09 |
12 |
1.5/0.059 |
18.9/0.744 |
397/267 |
TP39-2Y(L)2Y-18P09 |
18 |
1.7/0.067 |
21.7/0.854 |
542/364 |
TP39-2Y(L)2Y-25P09 |
25 |
1.7/0.067 |
24.7/0.972 |
708/476 |